DigitalTrak 2 Compact Digital Valve Positioner
The IMI STI DigitalTrak 2 is an intelligent electro pneumatic valve positioner delivering fast, accurate control with simplified setup, diagnostics and reliable operation in demanding processes.
Microprocessor control compares command and actual position to overcome friction, improving response speed and achieving precise, stable valve positioning.
Autotuning, onboard display and diagnostics simplify calibration, commissioning and troubleshooting, reducing setup time and ongoing maintenance effort.
Heavy duty construction with fail in place on signal loss and an integrated position transmitter improves safety, reliability and system integration.
Features
The IMI STI DigitalTrak 2 is an intelligent electro pneumatic valve positioner designed to improve control accuracy, reliability and ease of use in industrial process applications. Using microprocessor‑based control, it continuously compares the input signal with the actual valve position and precisely regulates air supply to the actuator. This enables fast, stable positioning even where friction or unbalanced forces would typically reduce performance.
DigitalTrak 2 supports simple commissioning through an integrated autotuning function and local display, allowing calibration and setup to be completed quickly and consistently. Built‑in diagnostics provide clear insight into positioner and valve behaviour, helping operators maintain optimal performance and reduce unplanned downtime.
Designed for heavy duty service, DigitalTrak 2 operates reliably across a wide temperature range and integrates key safety features such as fail in place on loss of signal. An integrated position transmitter further simplifies system design, making DigitalTrak 2 a practical replacement for conventional positioners in modern control systems.
Key features
Intelligent electro pneumatic valve positioner
Direct HART communication capability
Designed as a direct replacement for conventional positioners
Microprocessor based control architecture
Continuous position feedback via internal sensors
Automatic calibration and autotuning function
Integrated local display for setup and adjustment
Built in auto diagnostic functionality
Integrated position transmitter
Fail in place function on signal loss
Specifications
Certification
IP 65
Operating Pressure (bar)
1.4 to 7
Housing Material
Anodised Aluminium
Flow (Cv)
0.12
0.12
Ambient Temperature (°C)
-40 to 80
Signal
4-20 mA