BLOG
Keep molecular sieve dryers running: A smarter approach to valve replacement

Written By IMI Publications
November 30, 2026
In LNG, chemical, petrochemical and refinery operations, removing water from gas streams is crucial for operational success. Left in the stream, moisture can damage downstream equipment and processes.
Molecular sieve dryers fulfil this critical role by adsorbing water from the gas stream, although reliable drying also depends on the valves that control flow through the system. These valves must repeatedly open, close and seal while operating under highly demanding and changeable process conditions.
At the petrochemical plant in Qatar, problems with the conventional trunnion ball valves installed there were affecting the reliability of a molecular sieve dryer. The continuous thermal cycling when combined with molecular sieve particles in the process, was contributing to significant valve damage.
But the challenge was not simply to replace the damaged valves. It was also to understand why they were failing and to identify a replacement technology that would be better suited to the actual operating conditions.
The impact of choosing the wrong valve
Molecular sieve dryers operate through adsorption, regeneration and cooling stages. During adsorption, water molecules adhere to the molecular sieve material, thereby removing moisture from the gas stream. The sieve is then regenerated to remove accumulated water, cooled, and returned to adsorption service.
At this plant, each dryer has multiple towers cycling through these operating stages. Each tower had multiple valves controlling the inlet and outlet flows. And performance depends on these valves opening, closing and sealing reliably throughout repeated the adsorption and regeneration cycles.
For this particular customer, one of the biggest challenges was the temperature differential across the valves. Temperatures could reach nearly 300°C upstream, while being only 10 to 15°C downstream. So, while their existing system used trunnion ball valves, under these conditions the high upstream temperature caused thermal expansion, which could have caused the ball to become stuck against the seat.

Molecular sieve dryers support LNG processing by removing moisture from the gas stream, with valves controlling flow throughout repeated operating cycles.
Temperature, however, was not the only problem facing the facility’s engineering team. Molecular sieve particles were also present in the process medium, and the risk was that they could become trapped between the ball and seat, thereby contributing to further damage to the valve.
Therefore, rather than simply replacing the valves like-for-like, the customer needed to understand the root causes of the failures. Ultimately, they needed to find a valve better suited to the dryer's conditions.
Understanding why the existing valves were failing
Working with the facility’s process team, IMI engineers conducted a detailed assessment of the process parameters and the existing valve design. Their analysis identified several characteristics of the existing trunnion ball valves that were contributing to the problem:
Spring-energised double-seat sealing and a back cavity created an area where particles from the process medium could accumulate and damage the seat.
The existing tungsten carbide coating, identified as suitable for temperatures up to 200°C for this application, was also being exposed to temperatures approaching 300°C, resulting in coating deterioration.
Continuous contact between the ball and seat throughout the quarter-turn movement increased friction and wear during every operating cycle.
The team’s findings demonstrated why understanding the operating environment was fundamental to the facility's decision to make the correct replacement. A like-for-like replacement risked recreating the same problems. So, any replacement technology, instead, needed to address the specific combination of temperature, thermal expansion, particles, repeated cycling and sealing requirements found in the dryer.
Selecting a valve around the application
The findings were presented to the petrochemical plant’s process team, along with a recommendation for an alternative valve: the IMI C-Rex™ Double Eccentric Segmented Ball Valve. Several characteristics of the IMI C-Rex™ design directly addressed the failure mechanisms identified during the assessment.
The IMI C-Rex™ is torque-seated. It features a static seat and lacks the same back-seat arrangement, which reduces the areas where molecular sieve particles may accumulate. A metal-to-metal seat and a chromium carbide coating provide materials better suited to the high operating temperatures that prevail in the application.
The design also reduces contact between the C-ball and seat. The two are in contact during only the initial 3° of movement, after which there is no contact until closing. This feature reduces friction and wear compared with continuous rubbing throughout the full quarter-turn. It also lowers the force required to operate the valve.
Taken as a whole, these features provided the petrochemical facility with a valve solution carefully selected to match the conditions that had caused the previous valves to fail.
Building customer confidence in the solution
Technical suitability was only part of the customer's decision. To demonstrate C-Rex's experience in demanding applications, we provided the customer with details of the valves currently installed at oil refining facilities worldwide. This evidence, together with the team's responses to technical questions throughout the evaluation process, helped build confidence in the proposed replacement.
Process licensor approval was another critical requirement for the project. For an application of this importance, the proposed valve solution needed to meet not only the customer’s technical and operational requirements, but also the specifications established by the process licensor.

The IMI C-Rex valve underwent technical review and received process licensor approval for the customer’s molecular sieve dryer application.
IMI C-Rex™ has previously received approval from major process licensors for demanding applications. For this project, the proposed solution underwent the required technical review, resulting in process licensor approval for C-Rex™ valves to be supplied for the specific application. This represented an important milestone in the project, providing additional assurance that the C-Rex™ solution met the process requirements and supporting the customer’s decision to proceed with the technology.
The contract was secured in May 2025, initially covering two damaged valves in the regeneration service and installation expected in early 2027.
From two replacement valves to a longer-term opportunity
The initial two-valve replacement project was the first step toward addressing the broader requirements of the molecular sieve dryer. At the time the contract was awarded, a further 16 valves had been identified as potential replacements within the dryer, with additional opportunities across the plant's remaining dryers.
The initial installation also created an opportunity to demonstrate the performance of IMI’s C-Rex™ ball in the application. Subject to the successful operation of the first two installed valves and the appropriate review process, the project could serve as a valuable reference for future IMI C-Rex™ opportunities requiring broader Technip approval.
Why operating conditions should drive valve replacement
This project demonstrates an important principle in valve replacement: when a valve fails, replacing it with the same type of valve may not resolve the underlying problem. So, understanding why the valve failed in the first place can prevent the same failure mechanism from being repeated.
For a molecular sieve dryer, valve selection needs to consider factors including:
Maximum and minimum operating temperatures
Temperature differentials and thermal cycling
Particles and contaminants within the process medium
Valve operating frequency and cycling
Seat and coating materials
Sealing requirements
Operating torque
Maintenance requirements
Expected service life
In this application, understanding the interplay between temperature, thermal expansion, molecular sieve particles, and repeated operation was critical. By assessing those conditions before selecting the replacement, the customer could move away from simply responding to damaged valves towards a solution tailored to the process's actual demands.
C-Rex™ Double Eccentric Segmented Ball Valve certifications and approvals
C-Rex™ is available with a range of certifications, testing and approvals, including:
Fire safe: API 607 / ISO 10497 / API 6FA SIL 3 by TUV
Low fugitive emissions: ISO 15848-1 DVT performed, such as PR2 endurance testing 15,000 cycles, Shell DVT
Bidirectional tightness: API 598 / API 6D
Marine approvals: ABS / DNV-GL / BV
PR2 approval
Endurance testing: 15,000 cycles
TAT / DVT tested
CRN for Canada
Rethinking valve replacement
The lesson from the Qatar project goes beyond a single valve or molecular sieve dryer. Any valve replacement exercise should start by asking why the existing valve is no longer providing the required performance. Understanding the technical specifications, operating environment, process conditions and maintenance requirements can then reveal whether a different valve technology could provide a more suitable long-term solution.
With more than 350 valves across our technology portfolio, from butterfly and ball valves to customer-engineered control valves, IMI’s engineers work with our customers to understand their applications. We then identify the solution suited to the technical requirements, operating context, maintenance needs, and, of course, the available budget before creating the best technology solution for you.
For the plant’s molecular sieve dryer, that process led to the IMI C-Rex™: a valve specifically selected to address the temperature, particulate, and cycling challenges affecting the existing installation.
Rather than simply replacing a damaged valve, the project demonstrates the value of rethinking valve replacement in light of the failure cause and the application's demands.
To discover more about our C Rex™ valve technologies, please visit C-Rex - Double Eccentric Segmented Ball Valve™