Data‑driven analysis of thermal loads to improve plant reliability in flexible power plant operation.
The increasing share of renewable energy sources has led to fundamental changes in the operating profiles of thermal power plants. Frequent start‑ups and shutdowns, as well as rapid load changes, impose high thermo‑mechanical stresses on components and piping systems. Consequently, damage such as cracking, leakage, and unplanned outages has become more frequent, with significant economic and safety implications.
This paper presents a system‑wide, predictive analysis approach that combines operational data from process control systems with plant documentation and physics‑based modelling. The objective is to identify damage‑relevant operating conditions and their root causes in control logic, operating practice, and plant configuration at an early stage. Drawing on experience from numerous applications in thermal and combined cycle power plants, the paper demonstrates how targeted adjustments can significantly reduce thermal stress and sustainably prevent recurring damage. In addition to improved reliability and occupational safety, optimised operating strategies and more stable temperature control led, in selected applications, to net efficiency improvements of up to 1.5% and very short return‑on‑investment periods. The presented approach contributes to the reliable and economic integration of flexible power plants into future energy systems.
1. Introduction
Thermal power plants continue to play a crucial role in ensuring security of electricity supply, even as energy systems undergo rapid transformation. At the same time, their operational role has changed significantly. Many plants originally designed for steady base‑load operation are now required to operate flexibly, responding to fluctuating generation from renewable energy sources. In Europe in particular, daily start‑stop cycles, short start‑up times, and frequent load changes have become standard practice.
These altered operating requirements subject plant equipment to loads that were often not fully accounted for in the original design assumptions. Piping systems, valves, and components are exposed to steep temperature gradients, rapid temperature changes, and pronounced cyclic stresses. Damage often develops gradually and remains undetected over long periods, until leakage or failure occurs. The resulting unplanned outages are associated with substantial financial losses and increased safety risks for plant personnel.
2. Typical damage mechanisms in flexible operation
2.1 Thermo‑mechanical stress and fatigue
A key damage mechanism in flexible power plant operation is thermo‑mechanical fatigue. Rapid heating and cooling during start‑up, load changes, and shutdown generate non‑uniform temperature distributions within components and piping. These induce local thermal stresses which, under cyclic loading, can lead to crack initiation and propagation.
2.2 Critical systems and components
Operational experience across a wide range of plants shows that systems involving direct interaction between hot steam and spray water are particularly susceptible. These include boiler attemperators, desuperheaters, turbine bypass systems, and associated high‑temperature steam piping. Cracks frequently occur in pipe bends, weld seams, and valve bodies, often remaining undetected until advanced damage is present.
2.3 Influence of design, control, and operation
Thermal stress alone rarely explains observed damage patterns. In many cases, unfavourable installation geometries – for example, spray water injection points located close to pipe elbows – prevent sufficient mixing of hot and cold media, leading to local quenching. Furthermore, control strategies and parameters inherited from commissioning phases are often ill-suited to today’s highly cyclic operating modes, leading to unstable temperature control and excessive spray activity.
3. Limitations of conventional maintenance approaches
To ensure availability and safety, operators rely on periodic inspections, non‑destructive testing, and preventive maintenance programs. While indispensable, these approaches are largely reactive. Damage is often detected only after cracks have already formed.
Distributed control systems provide large volumes of operational data but typically lack insights into cumulative damage mechanisms. Analysing long‑term trends and subtle patterns requires significant time and specialised expertise, which is often limited in day‑to‑day operations. As a result, similar damage may reoccur even after repairs, because the underlying causes are not systematically addressed.
4. Need for a system‑wide predictive analysis
Advances in digitalisation have made high‑resolution operational data widely available. When analysed in a structured manner, this data provides detailed insight into actual plant behaviour under flexible operating conditions.

System-wide analysis combines operational data, control logic and plant configuration to identify damaging conditions before failures occur.
A predictive approach does not assess individual components in isolation, but evaluates the interaction between process conditions, control logic, and plant layout. Integrating operational data with plant documentation and physics‑based models enables identification of damaging operating conditions long before physical degradation becomes evident.
5. Methodological approach and implementation
The analytical framework used by IMI INSYT combines time-series data from the process control system with engineering documentation, such as P&IDs, isometric drawings, and technical specifications. Key variables typically include temperatures, pressures, mass flows, valve positions, and operating states during start‑ups, load changes, and shutdowns.
The analysis focuses on:
temperature gradients and rates of temperature change
control stability and control quality during transient operation
frequency, duration, and intensity of spray water injection
cyclic loading patterns linked to the operating profile
Assessments are carried out remotely without interfering with ongoing plant operation. Results are reviewed and discussed with plant operators in structured technical workshops, ensuring that site‑specific characteristics and operational practices are fully taken into account. Based on this process, tailored recommendations for improvements in operation, control logic, and plant configuration are developed.
6. Experience from implemented applications
Across numerous applications in combined cycle and conventional thermal power plants, recurring stress patterns have been identified that were previously not evident in routine operation. Despite varying plant designs, similar root causes emerged, particularly at the interface between control strategy, operating practice, and system configuration.
In many cases, control parameters dating back to commissioning were found to cause unstable temperature behaviour under today’s highly cyclic operating conditions. In other applications, insufficient drainage of steam lines significantly contributed to increased thermal stresses and recurrent cracking.
Through targeted measures – such as adjustments to control logic, optimisation of plant operating strategies, or modifications to system configuration – thermal gradients were significantly reduced. In several plants, previously recurring damage was no longer observed after the implementation of the recommended measures.
In addition to improved structural integrity, some applications demonstrated positive secondary operational effects. Eliminating efficiency‑relevant losses caused by unsuitable operating practices, combined with more stable temperature control, resulted in net efficiency improvements of up to 1.5% in selected applications. These effects were particularly evident in plants exposed to frequent load changes and start‑up cycles.
7. Benefits for operation, safety, and economics
7.1 Improved reliability and availability
Early identification of damage‑relevant operating conditions significantly reduces the likelihood of unplanned outages. Component lifetime is extended, and overall plant availability increases, especially during periods of high system demand.
7.2 Enhanced occupational safety
Cracks and leakages in high‑temperature steam systems pose serious safety risks. By proactively reducing thermo‑mechanical stresses, the probability of sudden failure events is lowered, improving safety for operating and maintenance personnel.
7.3 Economic impact and return on investment
Avoiding unplanned shutdowns reduces costs associated with emergency repairs, replacement components, scaffolding, and lost revenue. Maintenance activities can be planned more effectively using condition‑based strategies.
In many applications, implementation of the recommended measures required only limited investment. As a result, a return on investment was achieved after only a few months. Improved control stability and optimised operating practices additionally contributed to higher overall plant efficiency, further strengthening economic performance.
8. Relevance in the context of the energy transition
Flexible thermal power plants remain indispensable for ensuring system stability in energy systems with a high share of renewable generation. Optimising the operation of existing assets helps maintain this role safely and economically.
Beyond security of supply, improved operational efficiency supports sustainability objectives by reducing unnecessary fuel consumption, limiting material replacement, and minimising the environmental footprint associated with frequent repairs and outages.
9. Summary and conclusion
The increasing flexibility required of thermal power plants has exposed many systems to operating conditions beyond their original design assumptions. Resulting thermo‑mechanical stresses have led to higher damage rates that cannot be sufficiently addressed through conventional, reactive maintenance strategies alone.
A data‑driven, physics‑based, system‑wide analysis enables early identification of root causes and targeted mitigation measures. Experience from numerous successful implementations demonstrates that applying such an approach through IMI INSYT can sustainably improve plant reliability, safety, and economic performance, supporting the long‑term role of flexible thermal power plants in evolving energy systems.
This article originally appeared in German in VGBE Energy Journal in October 2026.