How our Retrofit3D™ trim upgrade solution boosted a European power plant’s performance

CASE STUDY

How our Retrofit3D™ trim upgrade solution boosted a European power plant’s performance

IMI Publications

Written By IMI Publications

November 18, 2026

Overview

In high-pressure power applications, spray water valves are vital to ensuring reliable operation and precise control. However, the valves wear away quickly under demanding conditions like cavitation and extreme pressure drops, leading to costly maintenance and unexpected shutdowns.

This case study highlights how IMI’s Retrofit3D™ trim upgrade solution helped transform a challenging valve application in a European power plant. By combining additive manufacturing, custom engineering, and a retrofit-friendly approach, the solution reduced downtime and restored stable flow control without replacing the entire valve assembly.

Design conditions:

  • Temperature: 150°C

  • Pressure: 124 bar (1800 psig)

The challenge

A major energy plant in Austria had been operating spray water valves fitted with conventionally manufactured VSG2 trims. These trims encountered frequent wear due to high-pressure drop conditions up to 1200 psig and cavitation effects within the valve, reducing component life.

This led to frequent, costly trim replacements and unplanned shutdowns, generating higher maintenance costs and significant production time losses due to downtime. Beyond operational performance, a key driver for this upgrade was the need to streamline internal valve components and introduce a more robust, proprietary design, particularly important in municipal and regional markets where replication of conventional trim designs is a known challenge.

The solution

The valve required precise flow control to operate within a low Cv range (0.08 to 3.88) while handling severe pressure drops. We therefore decided to engineer a disc stack trim to reduce cavitation and wear while ensuring accurate control at low flow conditions.

Among the common issues we observed at minimum flow near the seat were damage to the trim and flow, internal leakage, accelerated wear of the valve set, and increased maintenance frequency and cost. We evaluated the passage geometry to meet the required Cv values while matching the existing valve stroke.

Pressure and velocity profile through a control valve showing pressure falling below vapor pressure, causing flashing and cavitation.

Pressure and velocity profile across a control valve illustrating pressure drop below vapor pressure leading to flashing, and subsequent cavitation.


We subsequently created a unique design featuring two passage geometries, house and square (labs), to optimise the inlet area and Cv performance within the 0.08 to 3.88 mm range. In traditional trims, complex geometries do not always perform well under certain conditions and often need frequent replacements. Therefore, we suggested IMI stacks designed to provide speed control, high characterisation, and long stroke, ensuring excellent controllability under all flow conditions.

The original VSG2 valve seat had a bore diameter of 14 mm. Our initial calculations indicated that reusing the 14 mm seat with a 5/8” disc stack did not support the required process performance. Rather, increasing to a 1” DS proved ineffective, as it could not control the Cv for critical process conditions, particularly where a larger seat diameter (21.65 mm) was required.

To resolve this, we carried out an analysis to determine an optimal balance between seat size and trim performance. The final solution involved customising the seat bore to 15 mm and designing a tailored 0.75” DS trim. This configuration met the process control requirements and customer specifications, improving performance without compromising valve compatibility.

We conducted flow testing using a 3D-printed test puck to simulate actual conditions for applications with very low or high CV requirements and custom trim designs. Each disk we used in the stack was individually printed and tested to identify any clogged or underperforming passages.After confirming that the flow performance was within ±10% of the target Cv, we printed the final disk stack and shipped it to the customer. This upgraded design resolved previous performance issues and reliably met the customer’s expectations.

The agreed solution was a retrofit trim upgrade kit, including a disc stack, seat, stem, and valve soft goods kit.

This solution ensured that Linz AG’s facility needed fewer components, reducing operating costs and improving parts reliability. It also meant they could retain their existing pressure relief parts without welding, pipe modifications, or hydrotesting. This makes retrofitting even more valuable given that VSG2 parts are increasingly complex to source.

Cross-sectional diagrams comparing conventional and retrofit control valve trim designs and their principal components.

The benefits

Overall, we improved the plant's reliability through a customised 0.75” disc stack and 15 mm seat configuration, significantly reducing cavitation and wear and extending trim life. We also helped reduce the facility’s maintenance downtime by recommending longer-lasting components that led to fewer maintenance cycles and minimised unplanned plant shutdowns.

The optimised flow passages and accurate Cv matching ensured stable operation across the complete control range (0.08 to 3.88) and enhanced the plant’s process control.

Our solution reduced spare part replacements, maintenance, and labour costs, contributing to overall cost savings.

The new trim design was fully compatible with the existing valve body and actuator, requiring no significant modifications. Our rigorous flow testing and Cv validation ensured that the final product met performance expectations within ±10%, eliminating historical issues.

The solution featured a custom 0.75” disc stack and optimised 15 mm seat bore.

Conclusion

Our retrofit trim upgrade solution significantly improved the energy facility's valve reliability, reduced unplanned downtime, and restored process efficiency while minimising the need for significant system modifications. This demonstrates the value of precision engineering and additive manufacturing in solving complex flow control problems. By doing so, we are delivering measurable benefits to our customers worldwide.

Cutaway illustration of a cylindrical disc stack trim with an individual disc showing multi-path flow passages.

Disc stack trim featuring multiple engineered flow passages for precise flow control.


Our engineering team successfully addressed the customer’s cavitation, low Cv control, and high maintenance frequency challenges in their existing VSG2 valve trims through a tailored engineering approach. We delivered a design that met stringent performance requirements and aligned with the existing valve and actuator assembly by implementing a retrofit solution.

Need expert input on a similar challenge?

IMI specialists can help you explore the right approach for your operational goals, technical questions or next steps.
Person on shop floor viewing a monitor with a KPI board in the background.