Undersized valve trim upgrade using Retrofit3D

CASE STUDY

Undersized valve trim upgrade using Retrofit3D

IMI Publications

Written By IMI Publications

March 24, 2023

The Challenge

A major offshore oil & gas facility, located 150km off the coast of Nigeria, was spending valuable time investigating problems experience by its second stage water transfer pumps. On closer inspection, it became clear that the valve on the mini flow line was too small for the flow through the pump. The valve was designed to handle a maximum flow of 257 m^3/h, while the actual required flow was 310m3/h – putting a strain on the system.Undersized valves experience a higher pressure drop across the valve to maintain adequate flow and exhibit limited flow capacity. The restrictions in the valve can cause a build-up of pressure, risking damage to upstream pumps or other equipment. An undersized control valve generally cannot deliver sufficient flow rates under maximum load conditions.

Faced with these problems, the customer turned to IMI CCI (part of IMI’s family of specialist companies) for help.

Close-up of IMI CCI multi-path, multistage trim with precision perforations for optimised flow control.

Close-up of IMI CCI’s multi-path, multistage trim design featuring precision-engineered perforations and flow channels. This configuration ensures optimal performance by managing pressure drop and minimising erosion in severe service valve applications.


The Solution

IMI CCI’s specialists worked closely with the plant maintenance engineer to carry out a full review of the system and its actual operating conditions. The customer was looking for a cost-effective solution that did not involve replacing the entire valve.

Having reviewed the original specifications, including the requirement for multi stage control to handle the high pressure drop, IMI CCI’s engineers proposed an upgrade of the valve trim using IMI’s state-of-the-art Retrofit3D solution. Retrofit3D harnesses the power of additive manufacturing (or 3D printing) to design and manufacture custom-made valve trim. The bespoke trim is tailored to a specific application and process and avoids the extra time and expense involved in changing the valve body.

IMI CCI’s engineers calculated that changing the trim from 5” to 6” would increase the valve’s capacity to meet the required flow co-efficient (Cv) for the process conditions. The entire trim assembly (seat and plug) was upgraded to the larger size, while the cage assembly was replaced with a single 3D-printed cage, incorporating multi-stage paths to reduce pressure. This cage would provide enhanced flow control by incorporating “tear drop” holes using an innovative 3D printing technique called direct metal laser sintering. Manufacturing the trim in Inconel 718, which provides enhanced resistance to the erosion caused by high velocity water, will also extend the service life of the valve.

This solution allowed the customer to reuse the existing valve body, bonnet, actuator and accessories, saving the cost of replacing those parts. Meanwhile, the new 6” trim was delivered within 12 weeks, dramatically improving the efficiency of the plant, as well as reducing maintenance cycles.

Need expert input on a similar challenge?

IMI specialists can help you explore the right approach for your operational goals, technical questions or next steps.