
BLOG
Next-gen steam conditioning for the energy transition

Written By IMI Publications
June 27, 2023
Adapting to High-Cycle Operation
Combined cycle power stations now run at higher frequencies. This means they need to power up and down as grid demand fluctuates, filling the supply gaps that renewables cannot meet. Higher cycling does help lower carbon emissions, as power stations only operate when needed and are not left idling when the demand for energy is lower.
The main problem is that they have not been designed to operate in this way. High cycling puts greater operational stress on both power stations and their key components, such as valves. This can lead to higher failure rates, which means more plant downtime and higher operating costs. Potentially, it also increases the number of safety issues for plant workers.
The cooling of superheated steam is one of the most critical operations performed in steam turbine power stations. The cooling is undertaken by the steam conditioning valve, which generally performs well under conventional low-cycling plant conditions. However, with power stations adapting to new demands that generate higher cycling frequencies, conditioning valves are now failing more frequently.
This means that there is a clear need for more robust plant components, not only to maintain the supply of electricity but also to minimise the threat of unplanned outages. Given the intermittent nature of renewable power, the availability of these facilities is now more than ever a key part of keeping decarbonisation on track.
Designing Resilience
Recognising the challenges customers face, IMI developed a high-performance steam conditioning valve able to function reliably under the testing conditions of today’s combined cycle power plants. The company’s research and development team began with the existing steam conditioning VLB2 valve which they then modified to manage the greater operational stresses that characterise high cycling. Developing the initial design meant that the manufacturing and installation of the new valve –the VLB3– was quicker, which helped avoid any unnecessary and costly downtime.

The VLB3’s uniform body thickness allows material to expand and contract at the same rate which reduces fatigue damage. The valve body also has smooth transitions that minimise thermal stresses. Meanwhile, conditioning at the outlet takes place with improved thermal separation of the steam and water flow paths, reducing problems in the critical area of injection. Collectively, these modifications significantly lower any potential failure points that may occur when a plant is cooling steam.
As Jackie Hu, Managing Director at IMI points out: “It was important to us to develop a conditioning valve capable of withstanding the stresses that come with a high cycle approach. Supporting renewables is a priority for IMI, and getting the VLB3 into plants quickly shows how we are able to understand plant operators’ needs and provide timely solutions that help them run more efficiently. This valve is a product of the teamwork, communication and problem solving required to bring innovation to an evolving industry like power generation.”
Keep in touch
Stay up to date on all the latest news and articles from IMI.

Keep in touch
Stay up to date on all the latest news and articles from IMI.


Keep in touch
Stay up to date on all the latest news and articles from IMI.
Engineering the future together
Looking for the perfect flow control solution? Our experts specialise in providing tailored solutions to meet your unique needs. Let us help you achieve optimal performance, efficiency and safety.