© 2025 IMI plc, All Rights Reserved
CASE STUDY
Written By IMI Publications
July 28, 2022
A leading energy provider had significantly increased oil production from a field in the Arabian Gulf. Higher production increased the pressure of the flow passing through its water injection system so much so that multiple control valves began to fail after a short period of operation, with severe cavitation damage to the valve trim. This resulted in high costs due to the need for frequent maintenance and trim replacement.
The smooth operation of the valves is essential not only to the efficiency and safety of the plant but helps to protect the environmentally sensitive bay in which the field is located. The bay provides livelihoods for coastal fishing communities and its ecosystem teems with marine life and habitats, from turtles to coral reefs. A miracle of engineering in the form of artificial islands allows the operator to tap into a vast oil and gas field while protecting the bay’s biodiversity.
The client asked IMI to investigate and recommend a solution.
Engineers from IMI analysed the current process conditions in the plant, including production volumes, the properties of the injected water, pressure, and temperature ranges. Valve problems are often wrongly attributed to the age of a plant and its components. More often than not, however, the components start to suffer because the operating conditions have changed. Valves are designed around a precise set of operating conditions, which govern the type and design of components and materials. When process conditions change, problems can arise, including excess vibration and noise, cavitation and leakages, as well as reduced control over the flow through the valve.
IMI’s engineers identified a change in the inlet pressure as the root of the problem. During earlier periods of operation, inlet pressure had been below 1000psig, but when production from the field increased significantly, inlet pressures rose to 2500psig, putting stress on the internal parts of the valve. Furthermore, water saline content is double that of seawater (70,000 ppm), as the plant is pulling the injection water from the reservoir and the fluid velocity exceeds 100 ft/sec through the valve.
In the past, operators would have had to replace the whole valve with a new one customised to the current process conditions, attracting significant costs and disruption. Now, with the advent of additive manufacturing – 3D printing – it is possible to retrofit a new valve trim to the existing valve, saving time and money.
IMI’s innovative Retrofit3D product has been designed to do just this. The team recommended replacing the valve trim with a custom-designed Retrofit3D solution. The key component would be an additively manufactured disk stack, using IMI’s renowned pressure-reducing DRAG technology that would meet the process conditions in the field.
The disk stack was manufactured using a specialist additive manufacturing process called Binder Jetting. Binder Jetting is made up of two components, a metal powder and a binder that binds the metal powder layers. It is called a “green component” which is subsequently sintered to provide the strength and material properties required. The disk stack, plug and seat ring were all manufactured in Stellite 6, an alloy with outstanding resistance to corrosion and wear
The new valve trim was designed, assembled, and tested before being installed.
Five months after the new trim was installed, the valve was disassembled and inspected to see how it had performed in real process conditions. The valve trim met all the field trial success criteria, including precise controllability of less than 5% deviation to the designed valve characteristics, seat leakage according to class IV of ANSI FCI 70-2 at full shut off, and no evidence of excessive erosion or wear.
After it was installed, the process condition was monitored closely. During the trial period of five months the operator was happy with the performance of the retrofitted valve.
IMI’s Retrofit3D provides a speedy and cost-effective solution to many valve problems, including those arising from a change in the process conditions.
Retrofit3D combines additive manufacturing – 3D printing – and traditional manufacturing techniques to engineer valve trims that are optimised for the process conditions.
Unlike traditional manufacturing techniques which are subtractive – ie, they remove material – additive manufacturing works by building components by ‘printing’ layer upon layer. This provides extra flexibility in valve design, as internal features and complex geometries can be incorporated that would be impossible to achieve with traditional manufacturing techniques. Additive manufacturing also allows for more efficient use of space, with disk stacks up to 40% smaller, which can be retrofitted into a wide range of valve bodies.
Additive manufacturing is a widely-used term, but covers many different, sophisticated techniques – and new techniques are constantly being developed. Laser Powder Bed Fusion (LBPF) or Direct Metal laser Sintering (DMLS) are among the most known technics for stainless steel and nickel based alloys printing, but IMI also uses Binder Jetting techniques for specialist applications requiring specific materials such as Stellite6.
IMI is at the forefront of additive manufacturing, having successfully used the technology for over ten years, and playing an active role in the industry, from the development and testing of materials, parts qualification, to standards development.
Stay up to date on all the latest news and articles from IMI.
Stay up to date on all the latest news and articles from IMI.
Stay up to date on all the latest news and articles from IMI.