Checkmark

Added to quote

Cart Icon

Your quote has no products.

Quick product entry

NEON Pressure Sensor Ex with remote pressure transducer
NEON Pressure Sensor and Pressure Gauge from the IMI TWTG product brand with visible labels and connectors.
NEON Pressure Sensor from the IMI TWTG product brand with top label and metal mounting bracket.
NEON Pressure Gauge and Sensor
NEON Pressure Gauge from the IMI TWTG product brand with green rim and dual metal connectors.
NEON Pressure Gauge and Pressure Sensor from the IMI TWTG product brand positioned side by side with visible cabling.
NEON Pressure Gauge from the IMI TWTG product brand with analogue dial displaying pressure in bars.

IMI TWTG

NEON Pressure Sensor with Optional Gauge (Ex)

Pressure sensor for industrial applications, designed for rapid, non-intrusive installation and continuous remote monitoring of process pressure.

  • Tick

    Versatile mounting system adapts to a wide range of pipework and pressure points, enabling quick, tool-free installation with minimal operational disruption.

  • Tick

    Dedicated LoRaWAN connectivity provides secure, near real time pressure data, even in hazardous or hard-to-access industrial environments.

  • Tick

    Built for reliability with ATEX/IECEx Zone 0 certification, robust construction for extreme temperatures, and a battery life of up to 10 years, reducing maintenance and maximising uptime.

Accurate pressure readings are critical for any facility’s safe and efficient operation.

As the energy-producing industry rapidly transforms into the digital age, engineers are beginning to achieve deeper clarity of facilities by adding increasingly more data measuring points. However, while data leads innovation, we understand that, in certain situations, traditional instrumentation can still play a vital role for engineers.

NEON Pressure Gauge and Pressure Sensor from the IMI TWTG product brand with coiled hose and labelled housings.

Connected gauge and sensor for accurate industrial pressure monitoring.


Addressing these demands, IMI has developed a new pressure sensor that is accurate, versatile, and robust. The NEON Pressure Sensor is available in several pressure ranges and various other options, including one with a Badotherm gauge. The analog meter addresses an engineer’s need for immediate visual feedback when performing manual inspections, delicate maintenance, or possible emergency procedures. This design is best for digital and analog workflows, with fewer failure points than competing installations.

NEON Pressure Sensors provide data for predictive maintenance and monitoring and issue alerts when tolerances are breached. They are retrofittable, with up to ten years of battery life, and communicate wirelessly via a local LoRaWAN network. The sensors are available with an IECEx / ATEX certification or as a non-Ex variant.

IECEx Class 0 / ATEX Zone 0 certified variant

Designed for industry from the very beginning, the IMI TWTG NEON product line is built to not only operate in industrial sites where explosive gasses are being handled but also all other elements that a sensor may be exposed to in the course of its lifetime (up to 10 years). It has been tested and certified to work in conditions from -40° to 70° Celsius without hampering performance. The devices are designed and engineered so that they can be safely and securely deployed in a wireless network and are remotely configurable, ensuring not only longevity but also reliability within an operation.

Quote
Accurate pressure readings are critical for safety and efficiency
Quote

Non-Ex variant

The NEON Pressure Sensor is now also available in a non-ATEX / IECEx certified version, tailored for industrial environments where such certification is not required. Built with the same standards as the ATEX / IECEx certified version, this sensor delivers the same accurate pressure readings.

This version is ideal for facilities outside of explosive zones, such as manufacturing, pulp and paper, water management, and automation, offering all the benefits of the known NEON capabilities and features without the need for intrinsic safety compliance.

With the trusted NEON form factor, full LoRaWAN compatibility, and industry-grade resilience, this sensor offers a powerful, cost-effective solution for widespread asset monitoring – engineered to perform for over a decade in the field.

Additional to the sensor’s extremely long lifetime, IMI delivers spare parts and product lifecycle support. The sensor can continue to be used with the correct refurbishment kit. This way, maintenance can be kept at a minimum.

NEON Pressure Sensor can be installed / mounted using its bracket with a band clamp or bolts. The cable between the transmitter and sensor part allows for flexible placing options and easy access on-site.

NEON product line – LoRa devices designed for heavy industry

The NEON product range supports all industrial customers moving towards LoRaWAN as the Industrial IoT network of the future. The LoRaWAN network gives industrial operations a secure solution, which has no vendor lock-in, scales up to tens of thousands of sensors, covers complete sites with only a small amount of gateways, and best of all – the low-power approach means that the lifetime of the NEON products can be extended dramatically. This international networking technology is quickly becoming the industry standard.

NEON stands for a standardised approach to collecting data points from within the operation and a general approach to creating integrated solutions with existing IT ecosystems.

Key features

Tick

LoRaWAN transmitter with remote pressure sensor or gauge

Tick

Process temperature -40°C to 80°C

Tick

IECEx zone 0 / ATEX zone 0 certified

Tick

10-year battery life (depending on environment)

Tick

Based on the highest security standards

Tick

100% ownership of data

Tick

Available with or without IECEx / ATEX Zone 0 certification

Tick

Visualisation via IMI’s SolidRed or any other IoT platform

Tick

Installation within live environments with continuous operation

Tick

Integration with existing data backends or DCS

10

Years of battery life

Range

−1 bar .. 1000 bar

Zone 0

ATEX Zone 0 / IECEx Zone 0

Case Study

Offshore annulus pressure monitoring with NEON pressure sensors and SolidRed

Annulus pressure monitoring is critical for maintaining well integrity. NEON pressure sensors combined with SolidRed enable continuous remote readings and real-time alerts, reducing manual checks and improving operational safety.
Large offshore oil rig platform at sunset with cranes and structures, set in calm sea under vibrant sky.

Specifications

Protocol

LoRaWAN (private LoRaWAN)

LoRaWAN Region

EU868 / US915 / AU915 / AS923-1 / AS923-2 / AS923-3 / AS923-4 / IN865

LoRaWAN Frequency Bands

869 MHz

915 MHz

923 MHz

Maximum RF output power

+14 dBm

Battery Rated Capacity (Ah)

17

Battery Life

10 years at 25°C (77°F) (Depending on environment)

Operating Temperature Range (Transmitter)

-40°C to 80°C (-40°F to 176°F)

Water and Dust Resistance

IP65

Firmware Features

Independent event-based message triggers: Above / Below

Adjustable measurement interval: Flexible 1-minute resolution (relative or absolute)

Adjustable measurement message send condition: Always / on condition

Certifications

ATEX / IECEx Rating: Ex II 1G Ex ia IIC T4 Ga

ATEX / IECEx Certificates: 22ATEX0004X / DEK22.0004X

cFMus Rating: IS Class I Division 1 Group ABCD T4; Class I Zone 0 AEX/Ex ia IIC T4 Ga

cFMus Certificates: FM22US0061X / FM22CA0043X

NEON Pressure Sensor Range

-14.5–130.5 PSI .. 0–14503.8 PSI (-1–9 Bar .. 0–1000 Bar) relative

Other ranges and types on request

NEON Pressure Sensor Accuracy

0.3%fs (full scale)

NEON Pressure Sensor Temperature Range

-30..120°C

NEON Pressure Gauge Range

0-14.5PSI..0-3625.9PSI (0-1Bar..0-250Bar) relative

Other ranges and types on request

NEON Pressure Gauge Accuracy

0.3%fs (full scale)

NEON Pressure Guage Temperature Range

-30..80°C

Asset Monitoring Software

Spot issues early with SolidRed

SolidRed software uses data from your facility’s sensors to give you clear reports and early alerts. Stay ahead of problems and keep your operations running smoothly.
Industrial tablet showcasing SolidRed analytics with dynamic green accent

Resources

Documents

file-name
IMI TWTG - NEON Pressure Sensor brochureNEON Pressure Sensor Trifold Aw DIGITAL.pdf
file-name
IMI TWTG - 6037 N02-09 NEON-Product-Sheet-Pressure-Gauge A76037 N02-09 NEON-Product-Sheet-Pressure-Gauge A7.pdf
file-name
IMI TWTG - NEON Ratiometric-Transmitter Datasheet DS-RT-02-00 4000 C2NEON Ratiometric-Transmitter Datasheet DS-RT-02-00 4000 C2.pdf
file-name
IMI TWTG - NEON Ratiometric-Transmitter Product-Manual DS-RT-02-00 4001 C1NEON Ratiometric-Transmitter Product-Manual DS-RT-02-00 4001 C1.pdf
file-name
IMI TWTG - 4004 N02-09 Control-Drawing A64004 N02-09 Control-Drawing A6 1 .pdf

Software

file-name
IMI TWTG - NEON-Ratiometric-Transmitter Communication-Protocol-v1 DS-RT-02-xx 4003 1 A2NEON-Ratiometric-Transmitter Communication-Protocol-v1 DS-RT-02-xx 4003 1 A2.pdf
file-name
IMI TWTG - codec rt 20230515T130128Z 7b9fd516codec rt 20230515T130128Z 7b9fd516.js
file-name
IMI TWTG - codec rt 20230515T130128Z 7b9fd516.plaincodec rt 20230515T130128Z 7b9fd516.plain.js

Need help finding the right product?

Our team can help you select the most suitable solution for your process and operating conditions.